Mfg Part Number: N3-103 | Alternate P/N: N3103 | Manufacturer: Northlake Engineering Inc |
NSN : 5950-00-856-0944 | Item Name : transformer power | CAGE Code : 50638 |
FSC : 5950 Coils and Transformers |
Thank you for your interest in NSN 5950-00-856-0944 manufactured by Northlake Engineering Inc. The particular NSN product you are looking for is listed alongside the part number N3-103, and is described as Transformer Power. As we have this item available, we invite you to request a quote for your comparisons by filling out our RFQ form below. Once you have completed our form, we ask that you provide us with details regarding target prices, quantities, and expected shipping time frame. In this way, we can provide you with a quote that meets your specifications and requirements.
Beyond NSN 5950-00-856-0944 manufactured under CAGE Code 50638, and other various Northlake Engineering Inc parts, Acquire NSN has a stock inventory of over 2 billion new, used, obsolete, and hard-to-find NSN parts N3-103 that work to meet the needs of a variety of industry verticals and applications. Acquire NSN operates under AS9120B and ISO 9001:2015 certification and FAA AC 00-56B accreditation to ensure the quality and authenticity of our offerings. We have developed an interface that simplifies the purchasing process with rapid response times for the industries we serve. Get started on the procurement process today and see why customers steadily rely on Acquire NSN for all their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-856-0944 Item Description: Transformer Power | 5950 | 008560944 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
N3-103 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.938 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.250 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | OPEN |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 420.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 75.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 90.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 130.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 18 WIRE LEAD |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.250 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.563 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.438 INCHES NOMINAL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 6.60 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 7.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 17.40 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |